Every batch comes with its paperwork.
Omnix Research has each batch tested by an independent laboratory and keeps the report that belongs to it. The guides below show how to read that report, whoever your supplier is.
- Batch no.
- Must match your label
- Laboratory
- Independent, named lab Who ran the test
- Method
- HPLC and mass spec How it was measured
- Result
- Within specification Limit printed beside it
What we stand behind
Four commitments that apply to every order, and that you can check for yourself.
Independent testing
Batches are analysed by third-party laboratories rather than in-house.
A report for every batch
Each batch number links to the report written for that batch.
Sealed and numbered
Orders ship sealed, with the batch number printed on every label.
U.S. fulfilment and support
Orders ship from the U.S., and a U.S.-based team answers by text and email.
Read a report the way a lab does
Short, practical guides to Certificates of Analysis, test methods and what to check when an order arrives.
They apply to any supplier, not only to us.
Reading reportsAnatomy of a lab report
The six fields on a Certificate of Analysis that do most of the work.
Anatomy of a lab report
The six fields on a Certificate of Analysis that do most of the work.
A Certificate of Analysis (COA) is a laboratory’s record for one batch. Six fields carry most of the meaning.
- Batch or lot number. Ties the report to a physical item. It must match the number on your label.
- Laboratory. The lab’s name and address, plus a report or sample ID you can quote back to them.
- Dates. When the sample was received and when analysis finished. Both should come after the batch was made.
- Methods. The techniques used for each result.
- Specification and result. The limit the batch had to meet, printed beside the measured value.
- Approval. The analyst or reviewer who signed the report off.
If a report is missing any of these, ask for the full version rather than a summary.
MethodsPurity and identity are different questions
Why a complete report usually carries two results, and what each one tells you.
Purity and identity are different questions
Why a complete report usually carries two results, and what each one tells you.
A purity result and an identity result answer separate questions. One without the other leaves a gap.
- Purity, often measured by HPLC, separates a sample into its components and reports what share of the total the main component makes up, as a percentage.
- Identity, often confirmed by mass spectrometry, measures molecular mass and checks it against the expected value.
A high purity figure says a sample is mostly one thing. An identity result confirms which thing. Look for both, and check that the chromatogram or spectrum is attached, not only the final number.
MethodsWhat contaminant panels report
How endotoxin, heavy metal and solvent results are measured and written down.
What contaminant panels report
How endotoxin, heavy metal and solvent results are measured and written down.
Some reports go beyond purity and identity and test for specific contaminants. Each panel should name its method and report a result against a limit.
- Endotoxin is typically measured with a LAL assay and reported in endotoxin units (EU) per unit of material.
- Heavy metals are typically measured by ICP-MS and reported in parts per million or per billion for elements such as lead, arsenic, cadmium and mercury.
- Residual solvents are typically measured by gas chromatography and reported against a limit for each solvent.
A result can only be read as passing when its limit is printed next to it. A number on its own cannot be judged.
DeliveriesSeals, labels and batch numbers
Packaging is part of the paperwork. What to check before you put anything away.
Seals, labels and batch numbers
Packaging is part of the paperwork. What to check before you put anything away.
- Check that the outer packaging and any tamper-evident seals are intact.
- Read the batch number on each label and match it to the report for that batch.
- Compare items and quantities against your order confirmation.
- Follow any storage instructions on the label once the parcel is opened.
- Photograph anything damaged, incorrect or missing before throwing the packaging away.
If something is wrong, email support@leadomnix.shop or text (813) 336-1475 with your order number and photos.
VerificationHow to confirm a report with the lab
Five steps to check that a report was issued by the lab named on it.
How to confirm a report with the lab
Five steps to check that a report was issued by the lab named on it.
- Find the laboratory’s name and the report ID on the Certificate of Analysis.
- Look the lab up yourself instead of using contact details printed on the report.
- Check whether the lab lists accreditation, such as ISO/IEC 17025, for the methods used.
- Email the lab with the report ID and ask them to confirm it was issued and has not been altered.
- Compare their answer with the copy you hold.
Many labs offer an online lookup by report ID. If a supplier will not name the lab behind a result, treat that result with caution.
Questions about a report?
Our U.S.-based team answers questions about testing, batch numbers and documentation by text and email.